Specifications
|
| Power Requirements: |
120/240 VAC
50/60 Hz ± 15%, 5VA |
| Output Relay: |
DPDT 10 Amp at 250 VAC
STATUS Contacts: 3 Amps 240 VAC |
Ambient Temperature
Electronics:
Probe: |
-40° to
+185°F (-40° to +85°C)
+250°F Delrin, +500°F Teflon |
| Pressure: |
500 PSI, ¾" Mount |
| Sensitivity
Setting: |
Adjustable Sensitivity to
< 1 Picofarad |
| Calibration: |
"Quick Set" Course/Fine
Single Turn Potentiometers |
| Fail-Safe: |
Switch Selectable High/Low |
| Time
Delay: |
Adjust .25 to 10 Seconds |
Enclosure
Probe:
Electronics: |
Cast Aluminum,
Bolt-on Cover
USDA Approved Finish
Plastic |
| Mounting: |
1 ¼" NPT or ¾"
NPT 316 SS |
| Pro Shield: |
Compensates For Material Build-up
On Sensing Probe |
Approval Ratings
Probe:
Electronics: |
NRTL/C
NEMA 4X, 5 and 12
Intrinsically Safe
Class I Group C & D
Class II Group E, F & G
NEMA 4X, 5 and 12 |
| Status Indicator: |
Internal LED Indicates Material
In Contact With Probe
|
| Probe Options: |
Standard, Flush Mount, Flexible
Extension, Teflon Sleeved, Extended Shield, Stubby |